Mokon Logo
Download Our Brochure

Xtreme-Therm for Severe‑Duty Industrial Applications

Mokon's Xtreme-Therm® line features high-performing equipment designed for severe-duty environments in industrial manufacturing applications. Our portable chillers, combination heating and chilling systems, and circulating water and oil temperature control systems are built with robust polyester powder coated steel cabinetry. These high-quality products provide long-lasting operation in harsh industrial environments, assuring you a trusted, reliable temperature control solution. Mokon can customize any system to fit your specific requirements.

Trusted Standard Features

  • Temperatures from 20°F to 600°F (-7°C to 315°C)
  • Polyester powder coated heavy-gauge steel cabinets
  • NEMA 4/12 panel with “Z” purge system suitable for Class I Division 2 locations
  • cULus 508A labeled panel
  • UL 98 disconnect switch
  • Microprocessor controller
  • Remote set point and retransmission control and communication capabilities
  • Open loop (direct injection) single circuit design
  • Incoloy sheathed heaters with NEMA 4 housings
  • TEFC motors
  • Liquid-filled pressure gauges
  • Water-cooled and remote air-cooled condensers

Customizable Options

  • Water system temperatures up to 300°F (149°C)
  • Hot oil heat transfer fluid system temperatures up to 650°F (343°C)
  • Process cooling down to -20°F (-29°C)
  • Heating capacity up to 500 kW
  • Chilling capacity up to 120 Ton
  • NEMA 4/12 panel with “X” purge system suitable for Class I Division 1 locations
  • NEMA 7 cast aluminum panel suitable for Class I Division 1 or 2 locations
  • Multi-zone circuits
  • High-efficiency pumps up to 10 Hp
  • Magnetic drive sealless pumps
  • Vented and pressurized tanks
  • Passivation/electro-polish surfaces
  • Tool-free access panels
  • Modulating cooling valve
  • Stainless steel leveling legs
  • Stainless steel and other custom finished cabinetry
  • Audible and visual alarms
  • SCR and solid-state relays
  • Remote interface electrical enclosures
  • Electronic controllers and sensors calibrated to ISO 17025 standards
  • Variety of communication capabilities
  • Remote start/stop

Xtreme-Therm Water System

circulating water temperature control system

Mokon's Xtreme-Therm circulating water temperature control system features advanced heating technology with temperatures up to 250°F (121°C). The high-performance design offers higher heat transfer rates with unmatched control efficiency and accuracy. Built with non-ferrous and stainless steel materials, the Xtreme-Therm water system manages excellent corrosion resistance and leak-free operation in a compact, easy to move unit.

Pump Flow Rate and Pressure Heating Capacity (kW) Connections (FNPT) Approximate Dimensions (L x W x H)
Process Supply/Drain
          Connections (FNPT)  
Pump Flow Rate and Pressure Heating Capacity (kW) Process Supply/Drain Approximate Dimensions (L x W x H)
1 Hp 25 GPM @ 25 PSI 9 18 24 1″ 1″ 42″ x 20″ x 37″
1½ Hp 40 GPM @ 32 PSI 9 18 24 1½″ 1″ 42″ x 20″ x 37″
3 Hp 60 GPM @ 34 PSI 9 18 24 1½″ 1″ 42″ x 20″ x 37″
5 Hp 80 GPM @ 38 PSI 9 18 24 1½″ 1″ 42″ x 20″ x 37″

Xtreme-Therm Heat Transfer Fluid System

heater transfer fluid system

Mokon's Xtreme-Therm circulating oil temperature control system meets process heating requirements up to 600°F (315°C). Our durable, high-quality oil systems feature the latest control technology, unique cool oil reservoir philosophy and unmatched electrical/safety standards to ensure precise process fluid temperature control.

Pump Flow Rate and Pressure Heating Capacity (kW) Connections (FNPT) Approximate Dimensions (L x W x H)
Process Supply/Drain
          Connections (FNPT)  
Pump Flow Rate and Pressure Heating Capacity (kW) Process Supply/Drain Approximate Dimensions (L x W x H)
3 Hp 40 GPM to 51 PSI 12 1½″ 1″ 45″ x 30″ x 60″
3 Hp 40 GPM to 51 PSI 24 1½″ 1″ 45″ x 30″ x 60″
3 Hp 40 GPM to 51 PSI 36 1½″ 1″ 45″ x 30″ x 60″
3 Hp 40 GPM to 51 PSI 48 1½″ 1″ 45″ x 30″ x 62″
3 Hp 40 GPM to 51 PSI 60 1½″ 1″ 45″ x 30″ x 62″

Xtreme-Therm Portable Chiller System

portable chiller system

Mokon's Xtreme-Therm portable chillers feature a scroll compressor that provides superior efficiency, unwavering reliability and quiet operation with a fluid temperature range of 20°F to 65°F (-7°C to 18°C). Mokon's portable chillers are available in air and water-cooled condensing, featuring high-quality components for increased life and decreased maintenance, giving you the durable equipment, you need for all your cooling solutions.

Capacity (BTU/Hr) Compressor Hp Process Pump Hp Flow Rate and Pressure Connections (FNPT) Tank Size (Gallons) Approximate Dimensions (L x W x H)
Air-Cooled1 Water-Cooled2 Process Water‑Cooled Condenser
Capacity (BTU/Hr)       Connections (FNPT)    
Air-Cooled1 Water-Cooled2 Compressor Hp Process Pump
Hp
Flow Rate and Pressure Process Water‑Cooled Condenser Tank Size (Gallons) Approximate Dimensions (L x W x H)
15,800 16,700 1* ¾ 15 GPM @ 32 PSI 1″ ½″ 10 38″ x 25″ x 38″
34,100 35,300 3 ¾ 25 GPM @ 30 PSI 1″ ½″ 15 50″ x 28″ x 39″
56,100 58,100 5 1 30 GPM @ 37 PSI 1½″ 1″ 20 58″ x 37″ x 45″
89,200 92,000 1 30 GPM @ 34 PSI 1½″ 1½″ 20 58″ x 37″ x 45″
117,900 121,400 10 35 GPM @ 37 PSI 1½″ 1½″ 20 58″ x 37″ x 45″
1. Air-cooled based on 50°F chilled water at 2.4 GPM/Ton and 90°F ambient air. Air-cooled condensers are remotely mounted in a non-hazardous area.
2. Water-cooled based on 50°F chilled water at 2.4 GPM/Ton and 85°F condensing water at 3 GPM/Ton.
* Standard Compressor on 1 Ton is reciprocating type.

Xtreme-Therm Heating and Chilling System

water-based temperature control system

Mokon's water-based Xtreme-Therm temperature control system offers a combination of heating and chilling in one superior package. A Mokon water system combined with a chiller integrates the benefits and features of both products into one compact, self-supporting unit. The Xtreme-Therm heating and chilling systems are available with a temperature range of 20°F to 250°F (-7°C to 121°C).

Capacity (BTU/Hr) Δ Compressor Hp Process Pump Hp Flow Rate and Pressure Connections (FNPT) Tank Size (Gallons) Approximate Dimensions (L x W x H)
Air-Cooled1 Water-Cooled2 Process Water‑Cooled Condenser
Capacity (BTU/Hr) Δ       Connections (FNPT)    
Air-Cooled1 Water-Cooled2 Compressor Hp Process Pump
Hp
Flow Rate and Pressure Process Water‑Cooled Condenser Tank Size (Gallons) Approximate Dimensions (L x W x H)
15,800 16,700 1*
Select a standard pump to meet Process conditions or specify performance needs.
Hp GPM and PSI FNPT
3/4 25 GPM @ 26 PSI 1″
1 30 GPM @ 32 PSI 1½″
2 50 GPM @ 32 PSI 1½″
3 60 GPM @ 34 PSI 2″
5 80 GPM @ 38 PSI 2″
½″ 10 38″ x 25″ x 62″
34,100 35,300 3 ½″ 20 50″ x 28″ x 63″
56,100 58,100 5 1″ 20 58″ x 37″ x 69″
89,200 92,000 7 ½ 1½″ 20 58″ x 37″ x 69″
117,900 121,400 10 1½″ 20 58″ x 37″ x 69″
Full Range chart is based on 1 single zone up to 24 kW heater with open circuit and fluid temperature range 20°F to 200°F (-7°C to 93°C).
1. Air-cooled based on 50°F chilled water at 2.4 GPM/Ton and 90°F ambient air. Air-cooled condensers are remotely mounted in a non-hazardous area.
2. Water-cooled based on 50°F chilled water at 2.4 GPM/Ton and 85°F condensing water at 3 GPM/Ton.
* Standard Compressor on 1 Ton is reciprocating type.
Δ Capacities shown need to be de-rated for heating system motor Hp used.