C3 Cold Climate Cooler System (Ethylene Glycol)

Model Capacity (Tons) Flow (gpm) Fans Hp Fans Qty Dimensions (L x W x H) Shipping Weight (lbs.)
FND124C-9-E23 20 57 2 2 130" x 48" x 52" 1,125
FND134C-9-E35 30 86 2 3 187" x 48" x 52" 1,582
FND134C-9-G29 40 115 2 3 187" x 48" x 52" 1,640
FND154C-9-E70 50 143 2 5 301" x 48" x 56" 2,369
FND153F-9-G43 60 172 2 5 301" x 48" x 56" 2,367
FND234C-9-G58 80 229 2 6 187" x 93" x 52" 2,799
FND254C-9-E140 100 286 2 10 301" x 93" x 56" 4,356
FND253F-9-G86 120 344 2 10 301" x 93" x 56" 4,358

C3 Cold Climate Cooler System (Propylene Glycol)

Model Capacity (Tons) Flow (gpm) Fans Hp Fans Qty Dimensions (L x W x H) Shipping Weight (lbs.)
FND124C-9-G19 20 53 2 2 130" x 48" x 52" 1,164
FND134D-9-G29 30 79 2 3 187" x 48" x 52" 1,670
FND224C-9-G38 40 105 2 4 130" x 93" x 52" 2,025
FND224F-9-G38 50 131 2 4 130" x 93" x 52" 2,146
FND234D-9-G58 60 157 2 6 187" x 93" x 52" 2,860
FND253F-9-F86 80 210 2 10 301" x 93" x 56" 4,257
FND263D-9-G86 100 262 2 12 358" x 93" x 56" 5,220
FND263E-9-G86 120 315 2 12 358" x 93" x 56" 5,310

■ - Based on 1 Ton of refrigeration equal to 12,000 BTUH.

◆ - Flows are based on cooling 2.8 GPM per Ton of 50% water/50% ethylene glycol.

●- Flows are based on cooling 2.8 GPM per Ton of 60% water/40% propylene glycol.


Chiller capacities are based on cooling from 60°F to 50°F with 35°F ambient air temperature.

Specifications are for operation at elevations under 1,000 feet above sea level.

Includes motor fusing and non-fused disconnect.

Standard cold climate cooler leg height is 22”; optional heights of 36", 48" and 60" are available upon request.

  • Warranty
    • 1 year on system

Standard electrical rating is 480 Volts, 3 Phase, 60 Hertz. Other voltages available @ 60Hz include 208, 240, 600 Volts and @ 50Hz 208, 240, 380, 400, 415 Volts. Note: reduced cooling capacity by 8% when operating @50 Hz. For higher tonnages and flow capacities, please contact Mokon for more information.