Redesigned for improved performance, energy efficiency and reduced space requirements for large flow and higher heating capacity applications, the HF-2 Series Heat Transfer Fluid System provides accurate temperature control up to 600° (315°C) with an option to go to 650° (343°C).
The HF-2 Series features a 12 kW heater canister mounted in the traditional Mokon “horizontal forced fluid flow” design, proven in our systems for over 50 years. This heater design, along with an all-welded construction, reduces internal piping which limits potential leak points, and results in reduced cabinet size and floor space required. The system also features Mokon’s unique “continuous flow” cool oil reservoir design to ensure accurate and safe process temperature control and cooling.
For a Recommended Heat Transfer Fluid List, click on this link.
|
| Hp |
Flow Rate & Pressure |
Number of
Zones |
Heating
Capacity
kW per Zone
(total kW) |
Total
Amps * |
Reservoir
Tank
Volume
(gallons) |
Cabinet
Dimensions
L x W x H
(inches) |
| 3 |
40 GPM
and up to 51 psi |
1 |
12 |
18.9 |
38 |
41 x 30 x 51 |
| 3 |
40 GPM
and up to 51 psi |
1 |
24 |
33.9 |
38 |
41 x 30 x 51 |
| 3 |
40 GPM
and up to 51 psi |
1 |
36 |
49 |
38 |
41 x 30 x 51 |
| 3 |
40 GPM
and up to 51 psi |
1 |
48 |
64 |
38 |
41 x 30 x 62 |
| 3 |
40 GPM
and up to 51 psi |
1 |
60 |
79.2 |
38 |
41 x 30 x 62 |
| 3 |
40 GPM
and up to 51 psi |
1 |
72 |
94.2 |
38 |
41 x 30 x 73 |
| 3 |
40 GPM
and up to 51 psi |
1 |
96 |
124.4 |
58 |
41 x 45 x 62 |
| 3 |
40 GPM
and up to 51 psi |
2 |
12 (24 kW) |
37.7 |
76 |
41 x 60 x 51 |
| 3 |
40 GPM
and up to 51 psi |
2 |
24 (48 kW) |
67.8 |
76 |
41 x 60 x 51 |
| 3 |
40 GPM
and up to 51 psi |
2 |
36 (72 kW) |
98 |
76 |
41 x 60 x 62 |
| 3 |
40 GPM
and up to 51 psi |
2 |
48 (96 kW) |
128.2 |
76 |
41 x 60 x 62 |
| 5 |
60 GPM
and up to 56 psi |
1 |
12 |
21.1 |
38 |
41 x 30 x 51 |
| 5 |
60 GPM
and up to 56 psi |
1 |
24 |
36.1 |
38 |
41 x 30 x 51 |
| 5 |
60 GPM
and up to 56 psi |
1 |
36 |
51.2 |
38 |
41 x 30 x 51 |
| 5 |
60 GPM
and up to 56 psi |
1 |
48 |
66.2 |
38 |
41 x 30 x 62 |
| 5 |
60 GPM
and up to 56 psi |
1 |
60 |
81.4 |
38 |
41 x 30 x 62 |
| 5 |
60 GPM
and up to 56 psi |
1 |
72 |
96.4 |
38 |
41 x 30 x 73 |
| 5 |
60 GPM
and up to 56 psi |
1 |
96 |
126.6 |
58 |
41 x 45 x 62 |
| 5 |
60 GPM
and up to 56 psi |
2 |
12 (24 kW) |
42.1 |
76 |
41 x 60 x 51 |
| 5 |
60 GPM
and up to 56 psi |
2 |
24 (48 kW) |
72.2 |
76 |
41 x 60 x 51 |
| 5 |
60 GPM
and up to 56 psi |
2 |
36 (72 kW) |
102.4 |
76 |
41 x 60 x 62 |
| 5 |
60 GPM
and up to 56 psi |
2 |
48 (96 kW) |
132.6 |
76 |
41 x 60 x 62 |
| 5 |
90 GPM
and up to 52 psi |
1 |
12 |
23.8 |
18 |
41 x 15 x 51 |
| 5 |
90 GPM
and up to 52 psi |
1 |
24 |
38.9 |
38 |
41 x 30 x 51 |
| 5 |
90 GPM
and up to 52 psi |
1 |
36 |
53.9 |
38 |
41 x 30 x 64 |
| 5 |
90 GPM
and up to 52 psi |
1 |
48 |
69.0 |
38 |
41 x 30 x 64 |
| 5 |
90 GPM
and up to 52 psi |
1 |
60 |
84.1 |
38 |
41 x 30 x 64 |
| 5 |
90 GPM
and up to 52 psi |
1 |
72 |
99.2 |
38 |
41 x 30 x 77 |
| 5 |
90 GPM
and up to 52 psi |
1 |
96 |
129.3 |
58 |
41 x 45 x 77 |
| 5 |
90 GPM
and up to 52 psi |
1 |
108 |
144.4 |
58 |
41 x 45 x 77 |
| 5 |
90 GPM
and up to 52 psi |
1 |
120 |
159.5 |
78 |
41 x 60 x 77 |
| 5 |
90 GPM
and up to 52 psi |
1 |
132 |
174.6 |
78 |
41 x 60 x 77 |
| 5 |
90 GPM
and up to 52 psi |
1 |
144 |
189.7 |
78 |
41 x 60 x 77 |
| 5 |
90 GPM
and up to 52 psi |
2 |
12 (24 kW) |
46.5 |
58 |
41 x 30 x 51 |
| 5 |
90 GPM
and up to 52 psi |
2 |
24 (48 kW) |
76.7 |
78 |
41 x 60 x 51 |
| 5 |
90 GPM
and up to 52 psi |
2 |
36 (72 kW) |
106.7 |
78 |
41 x 60 x 64 |
| 5 |
90 GPM
and up to 52 psi |
2 |
48 (96 kW) |
134.1 |
78 |
41 x 60 x 64 |
| 5 |
90 GPM
and up to 52 psi |
2 |
60 (120 kW) |
171.5 |
78 |
41 x 60 x 77 |
| 5 |
90 GPM
and up to 52 psi |
2 |
72 (144 kW) |
197.3 |
78 |
41 x 60 x 77 |
| 5 |
120 GPM
and up to 48 psi |
1 |
12 |
23.8 |
18 |
41 x 15 x 51 |
| 5 |
120 GPM
and up to 48 psi |
1 |
24 |
38.9 |
38 |
41 x 30 x 51 |
| 5 |
120 GPM
and up to 48 psi |
1 |
36 |
53.9 |
38 |
41 x 30 x 64 |
| 5 |
120 GPM
and up to 48 psi |
1 |
48 |
69.0 |
38 |
41 x 30 x 64 |
| 5 |
120 GPM
and up to 48 psi |
1 |
60 |
84.1 |
38 |
41 x 30 x 77 |
| 5 |
120 GPM
and up to 48 psi |
1 |
72 |
99.2 |
38 |
41 x 30 x 77 |
| 5 |
120 GPM
and up to 48 psi |
1 |
96 |
129.3 |
58 |
41 x 45 x 77 |
| 5 |
120 GPM
and up to 48 psi |
1 |
108 |
144.4 |
58 |
41 x 45 x 77 |
| 5 |
120 GPM
and up to 48 psi |
1 |
120 |
159.5 |
78 |
41 x 60 x 77 |
| 5 |
120 GPM
and up to 48 psi |
1 |
132 |
174.6 |
78 |
41 x 60 x 77 |
| 5 |
120 GPM
and up to 48 psi |
1 |
144 |
189.7 |
78 |
41 x 60 x 77 |
| 5 |
120 GPM
and up to 48 psi |
2 |
12 (24 kW) |
46.5 |
58 |
41 x 30 x 51 |
| 5 |
120 GPM
and up to 48 psi |
2 |
24 (48 kW) |
76.7 |
78 |
41 x 60 x 51 |
| 5 |
120 GPM
and up to 48 psi |
2 |
36 (72 kW) |
106.7 |
78 |
41 x 60 x 64 |
| 5 |
120 GPM
and up to 48 psi |
2 |
48 (96 kW) |
134.1 |
78 |
41 x 60 x 64 |
| 5 |
120 GPM
and up to 48 psi |
2 |
60 (120 kW) |
171.5 |
78 |
41 x 60 x 77 |
| 5 |
120 GPM
and up to 48 psi |
2 |
72 (144 kW) |
197.3 |
78 |
41 x 60 x 77 |
|
| |
|
*460/3/60 (additional voltages available; please consult factory)
Heat exchangers:40 and 60 gpm - 7.0 sq. ft. for single zone, except 96kW; 14 sq.ft. all other models
90 and 120 gpm - 21 sq. ft.
Connections: 40 and 60 gpm - 1-1/2" process, 3/4" water
90 gpm - 2" process, 1-1/2" water
120 gpm - 2-1/2" process, 1-1/2" water
For 650°F (343°C) systems, please consult factory.
|
|
 |
|
 |
| Standard Features |
| A• |
NEMA 12 electrical enclosure with disconnect switch |
| B• |
Powder coated cabinetry and electrical box |
| C• |
“Continuous Flow” cool oil reservoir |
| D• |
Heavy duty ball bearing casters |
| E• |
Cooling water connections |
| F• |
Centrifugal pump |
| G• |
Easily accessible process connections |
| H• |
Heater access panel |
| I• |
Insulated 12 kw heater manifold |
| J• |
High temperature safety shut-off switch |
| K• |
Glycerine-filled pressure gauges |
| L• |
Eurotherm microprocessor-based controller with scrolling text |
| M• |
NFPA 79 and UL labeled electrical sub-panel (not shown) |
|
|
Typical Flow Schematic
|
 |
| |
|
|
| |
|
|
| * Please consult factory for more information. |
 |
|
| • |
Additional Cooling Capacity |
| • |
Alarms |
| • |
Auto Air Purge |
| • |
Heat Exchanger Flow Control System |
| • |
Heater Selector Switch (Automatic) |
| • |
Heater Selector Switch (Manual) |
| • |
High-Temperature Stainless Steel Braided Hose |
| • |
Low Fluid Level Shut-Off |
| • |
Other Voltages, Phases, Frequencies |
| • |
Phase Indicator |
| • |
Process Fluid Purge via Switch |
| • |
Strainers |
| • |
Thermometers |
| • |
Control Options |
| • |
Blown Fuse Indication |
|
| |
| |
| Features of Standard and Optional Controls |
A variety of controls are available from Mokon to enhance the high performance of our systems. From solid state to microprocessor based, with communication capabilities to PLC type controls, Mokon can provide the type of control package right for your process.
|
| Eurotherm 3216 Series |
The Eurotherm 1/16 DIN (3216) microprocessor controller is now standard on the entire line of portable chillers, water and heat transfer fluid temperature control systems. This controller is operator friendly and easy-to-use. Standard features include a microprocessor PID controller for the highest accuracy in temperature control, a dual LCD display that shows set point and actual fluid temperature, and advanced PID overshoot protection with self-tuning capabilities for increased accuracy. Scrolling text messages deliver plain language messages to let users know exactly what is happening to the process.
There are optional 1/8 or 1/4 DIN controllers available, with high/low deviation alarm, remote set point and retransmission and serial communication. A five-year warranty comes standard with the controller. |
 |
|
| Custom Controls |
| Mokon’s ability to meet customers’ specific requirements is seen not only in custom system designs, but also in controls. Our engineers can custom design a control package that meets your specific processing needs, from brand name controls, to direct computer/host machine interfacing. All of which can be expected with the same quality and durability that our customers expect from our complete line of temperature control systems. |
|
| |