Chiller Systems

C3 Cold Climate Coolers

Mokon's C3 cold climate cooler design offers a cost-effective solution to process fluid cooling in cold weather areas. The dry coolers use ambient air temperature to cool fluid in a closed loop system that requires no make-up water or expensive chemical treatments.

  • Cooling capacities up to 120 Tons/1,440,000 BTU/Hr
  • Coils and headers made of seamless copper tubes
  • Coil support for ease of linear expansion of the condenser core
  • 1/2″ NPT drain and vent
  • Nonferrous wetted surfaces
  • Brazed connections
  • Single or multiple circuit designs
  • Closed loop system
  • Weather-resistant construction
  • Heavy gauge galvanized steel
  • Sectionalized cabinet with individual fan chambers
  • Weather-protected aluminum fans and blades
  • Fan motors feature permanently lubricated, sealed ball bearings
  • Includes motor fusing and non-fused disconnect control panel
  • Low ambient kits
  • Side access panels for easy coil inspection and cleaning
  • System allows for reduction of indoor chiller size and heat gain to room
  • Ideal when used with a Central Chiller/Pump Tank System
  • Variety of mounting legs and frames
  • Corrosion protective coatings
  • Local and remote electrical panels
  • Lower decibel ratings
  • Other voltages, phases, frequencies
  • Chillers up to 120 Ton with fluid temperatures down to -20°F (-29°C)
  • Pump Tank Systems and integrated chiller skid packages
  • Cooling capacities up to 5,500,000 BTU/Hr

Please consult factory for more information.

Cold Climate Cooler System (Ethylene Glycol)

Model Capacity1 (Tons) Flow Rate2 (GPM) Fans Hp Fans Qty Approx. Dimensions (L x W x H) Shipping Weight (lbs.)
FND124D-9-E023 20 57 2 2 130" X 48" X 52" 1,125
FND134D-9-E035 30 86 2 3 187" x 48" x 52" 1,582
FND134D-9-G029 40 115 2 3 187" x 48" x 52" 1,640
FND154D-9-E070 50 143 2 5 301" x 48" x 56" 2,369
FND153F-9-G043 60 172 2 5 301" x 48" x 56" 2,369
FND234D-9-G058 80 229 2 6 187" x 93" x 52" 2,799
FND254D-9-E140 100 286 2 10 301" x 93" x 56" 4,356
FND253F-9-G086 120 344 2 10 301" x 93" x 56" 4,358

Cold Climate Cooler System (Propylene Glycol)

Model Capacity1 (Tons) Flow Rate3 (GPM) Fans Hp Fans Qty Approx. Dimensions (L x W x H) Shipping Weight (lbs.)
FND124D-9-G019 20 53 2 2 130″ x 48″ x 52″ 1,164
FND134D-9-G029 30 79 2 3 187″ x 48″ x 52″ 1,670
FND224D-9-G038 40 105 2 4 130″ x 93″ x 52″ 2,025
FND224F-9-G038 50 131 2 4 130″ x 93″ x 52″ 2,146
FND234D-9-G058 60 157 2 6 187″ x 93″ x 52″ 2,860
FND253F-9-F086 80 210 2 10 301″ x 93″ x 56″ 4,257
FND263D-9-G086 100 262 2 12 358″ x 93″ x 56″ 5,220
FND263F-9-G086 120 315 2 12 358″ x 93″ x 56″ 5,310

  1. Based on 1 Ton of refrigeration equal to 12,000 BTU/Hr.
  2. Flows are based on cooling 2.8 GPM per Ton of 50% Water/50% Ethylene Glycol.
  3. Flows are based on cooling 2.8 GPM per Ton of 60% Water/40% Propylene Glycol.

Notes: Electrical service - 460 V, 3 PH, 60 HZ. Chiller capacities are based on cooling from 60°F (16°C) to 50°F (10°C) with 35°F (2°C) ambient air temperature. Specifications are for operation at elevations under 1000 ft. above sea level. Standard leg height is 22"; optional heights of 36", 48", and 60" are available upon request.