Mokon 2150 Elmwood Ave, Buffalo, NY 14207-1910 USA. Phone 716.876.9951 Fax 716.874.8048
HEAT TRANSFER FLUID SYSTEMS
» For process heating requirements up to 650°F (343°C)
» Available up to 144 kW and to 5 Hp with flow rates from 5 gpm to 120 gpm
» Heating and/or cooling with single, dual or triple zone configurations
  Read More
HEAT TRANSFER FLUID SYSTEMS

HTF HF-2 Series

Product Features
|
Options
|
Controls
|
Request Quotes/Literature
 
HTF HF-2 Series
Mokon's HTF HF-2 Series system provides accurate temperature control up to 600° (315°C) with an option to go to 650° (343°C) with improved performance, energy efficiency and reduced space requirements for large flow and higher heating capacity applications.

The HF-2 Series features a 12 kW heater canister mounted in the traditional Mokon horizontal forced fluid flow design, proven in our systems for over 55 years. This heater design, along with an all-welded construction, reduces internal piping which limits potential leak points.The system also features Mokon’s unique cool oil reservoir design to ensure accurate and safe process temperature control and cooling.

For a Recommended Heat Transfer Fluid List, click on this link. 

 
Hp Flow Rate & Pressure Number of
Zones
Heating
Capacity
kW per Zone
(total kW)
Total
Amps *
Reservoir
Tank
Volume
(gallons)
Cabinet
Dimensions
L x W x H
(inches)
3 40 GPM
and up to 51 psi
1 12 18.9 38 41 x 15 x 51
3 40 GPM
and up to 51 psi
1 24 33.9 38 41 x 30 x 51
3 40 GPM
and up to 51 psi
1 36 49 38 41 x 30 x 51
3 40 GPM
and up to 51 psi
1 48 64 38 41 x 30 x 62
3 40 GPM
and up to 51 psi
1 60 79.2 38 41 x 30 x 62
3 40 GPM
and up to 51 psi
1 72 94.2 38 41 x 30 x 73
3 40 GPM
and up to 51 psi
1 96 124.4 58 41 x 45 x 62
3 40 GPM
and up to 51 psi
2 12 (24 kW) 37.7 76 41 x 60 x 51
3 40 GPM
and up to 51 psi
2 24 (48 kW) 67.8 76 41 x 60 x 51
3 40 GPM
and up to 51 psi
2 36 (72 kW) 98 76 41 x 60 x 62
3 40 GPM
and up to 51 psi
2 48 (96 kW) 128.2 76 41 x 60 x 62
5 60 GPM
and up to 56 psi
1 12 21.1 38 41 x 15 x 51
5 60 GPM
and up to 56 psi
1 24 36.1 38 41 x 30 x 51
5 60 GPM
and up to 56 psi
1 36 51.2 38 41 x 30 x 51
5 60 GPM
and up to 56 psi
1 48 66.2 38 41 x 30 x 62
5 60 GPM
and up to 56 psi
1 60 81.4 38 41 x 30 x 62
5 60 GPM
and up to 56 psi
1 72 96.4 38 41 x 30 x 73
5 60 GPM
and up to 56 psi
1 96 126.6 58 41 x 45 x 62
5 60 GPM
and up to 56 psi
2 12 (24 kW) 42.1 76 41 x 60 x 51
5 60 GPM
and up to 56 psi
2 24 (48 kW) 72.2 76 41 x 60 x 51
5 60 GPM
and up to 56 psi
2 36 (72 kW) 102.4 76 41 x 60 x 62
5 60 GPM
and up to 56 psi
2 48 (96 kW) 132.6 76 41 x 60 x 62
5 90 GPM
and up to 52 psi
1 12 23.8 18 41 x 30 x 51
5 90 GPM
and up to 52 psi
1 24 38.9 38 41 x 30 x 51
5 90 GPM
and up to 52 psi
1 36 53.9 38 41 x 30 x 64
5 90 GPM
and up to 52 psi
1 48 69.0 38 41 x 30 x 64
5 90 GPM
and up to 52 psi
1 60 84.1 38 41 x 30 x 64
5 90 GPM
and up to 52 psi
1 72 99.2 38 41 x 30 x 77
5 90 GPM
and up to 52 psi
1 96 129.3 58 41 x 45 x 77
5 90 GPM
and up to 52 psi
1 108 144.4 58 41 x 45 x 77
5 90 GPM
and up to 52 psi
1 120 159.5 78 41 x 60 x 77
5 90 GPM
and up to 52 psi
1 132 174.6 78 41 x 60 x 77
5 90 GPM
and up to 52 psi
1 144 189.7 78 41 x 60 x 77
5 90 GPM
and up to 52 psi
2 12 (24 kW) 46.5 58 41 x 30 x 51
5 90 GPM
and up to 52 psi
2 24 (48 kW) 76.7 78 41 x 60 x 51
5 90 GPM
and up to 52 psi
2 36 (72 kW) 106.7 78 41 x 60 x 64
5 90 GPM
and up to 52 psi
2 48 (96 kW) 134.1 78 41 x 60 x 64
5 90 GPM
and up to 52 psi
2 60 (120 kW) 171.5 78 41 x 60 x 77
5 90 GPM
and up to 52 psi
2 72 (144 kW) 197.3 78 41 x 60 x 77
5 120 GPM
and up to 48 psi
1 12 23.8 18 41 x 30 x 51
5 120 GPM
and up to 48 psi
1 24 38.9 38 41 x 30 x 51
5 120 GPM
and up to 48 psi
1 36 53.9 38 41 x 30 x 64
5 120 GPM
and up to 48 psi
1 48 69.0 38 41 x 30 x 64
5 120 GPM
and up to 48 psi
1 60 84.1 38 41 x 30 x 77
5 120 GPM
and up to 48 psi
1 72 99.2 38 41 x 30 x 77
5 120 GPM
and up to 48 psi
1 96 129.3 58 41 x 45 x 77
5 120 GPM
and up to 48 psi
1 108 144.4 58 41 x 45 x 77
5 120 GPM
and up to 48 psi
1 120 159.5 78 41 x 60 x 77
5 120 GPM
and up to 48 psi
1 132 174.6 78 41 x 60 x 77
5 120 GPM
and up to 48 psi
1 144 189.7 78 41 x 60 x 77
5 120 GPM
and up to 48 psi
2 12 (24 kW) 46.5 58 41 x 30 x 51
5 120 GPM
and up to 48 psi
2 24 (48 kW) 76.7 78 41 x 60 x 51
5 120 GPM
and up to 48 psi
2 36 (72 kW) 106.7 78 41 x 60 x 64
5 120 GPM
and up to 48 psi
2 48 (96 kW) 134.1 78 41 x 60 x 64
5 120 GPM
and up to 48 psi
2 60 (120 kW) 171.5 78 41 x 60 x 77
5 120 GPM
and up to 48 psi
2 72 (144 kW) 197.3 78 41 x 60 x 77
 


*460/3/60 (additional voltages available; please consult factory)
Heat exchangers:40 and 60 gpm - 7.0 sq. ft. for single zone, except 96kW; 14 sq.ft. all other models 
90 and 120 gpm - 21 sq. ft.
Connections: 40 and 60 gpm - 1-1/2" process, 3/4" water
90 gpm - 2" process, 1-1/2" water
120 gpm - 2-1/2" process, 1-1/2" water

For 650°F (343°C) systems, please consult factory.